To locate the diagnostic port on your Hy-Brid Lifts Pro Series machine, you’ll need to remove the battery cover and two 7/16 in bolts. Next, slide out the lower control panel and locate the plug inside. Then, simply connect the plug to the EZcal Pro, and you’re ready to go!
RELATED POSTS
EZcal Pro Height Calibration on Pro Series Scissor Lifts
TOOLS NEEDED: This video walks you through the steps to calibrate height on a Hy-Brid Lifts Pro Series machine. Once the EZcal…How to Release the Brakes on the HB-1230
To manually release the brakes on an HB-1230 scissor lift, start at the rear of the machine. Reach in and…SB-1006 -PRO SERIES FRONT HUB WASHERS
During recent inspections, some washers used between the hub and retaining ring on the front casters of Hy-Brid Lifts Pro…